Cyhcs-ltp200a-sac
http://www.hallsensors.de/CYHCS-OL-RW1.htm WebIt can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor. Product Characteristics Excellent accuracy Very good linearity Accuracy independent from the position of premiary cable Lager measuring range Applications Photovoltaic equipment
Cyhcs-ltp200a-sac
Did you know?
http://www.hallsensors.de/CYHCS-E.pdf WebVA DIRECTIVE 7125 GENERAL PROCEDURES 1. PURPOSE. This directive defines acquisition and materiel management policies required to implement or supplement the …
WebCYHCS-B200 - Hallsensors.de EN English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian český русский български العربية Unknown WebCYHCS-RC2S Current Sensor Relation between Input Current and Output Voltage Take the sensor CYHCS-RC2S-100A-3 as sample, the relation between the input current and output voltage is shown in the table 1, Fig.1 and Fig. 2 Table 1. Relation between the input current and output voltage Input current (A) -200 -150 -100 -50 0 50 100 150 200
http://www.hallsensors.de/CYHCS-L.pdf http://www.current-sensors.de/CYHCS-OL-BW.htm
Webcyhcs-k3/br: ±15vdc: 50a - 600a: 0 ~ ±4v, 0 ~ ±5v: 1.0%: 0.5%-25°c - +85°c : 20.5 x 10.5: 2: cyhcs-bs5 +5v dc: 50a - 600a +2.5vdc ±1v: 1.0%: 0.5%-25°c - +85°c : 20.5 x 10.5: 3: cyhcs-bsr565 +5vdc: 50a - 600a +2.5vdc ±0.625v, reference +2.5vdc: 1.0%: 0.5%-25°c - +85°c : 20.6 x 10.5: 4: cyhcs-bt +12vdc, +15vdc, +24vdc: 50a - 600a +5vdc ...
WebCYHCS-D6 Current Sensor CYHCS-D6M-xxxx Molex Connector: Molex 22011042, 5045-04AG, 5051-04 I Operating instructions 1. Connect the terminals of power source, outputs respectively and correctly, never make wrong connection for DC current. 2. Temperature of the primary conductor should not exceed 120 °C. 3. Dynamic performances (di/dt and the ... great food to make for dinnerWebLinear Conveyor Module LCMR200. Advanced linear conveyor module with high speed transport. Repeatability : ±5μm. Maximum speed* : 2,500mm/sec. * When the conveying … flir wärmebildkamera software downloadWebChen Yang markalı CYHCT-C2TC-U50A-5P Menteşeli yankı etkisi DC akım sensörü ürüne ait fiyat ve teslim sürelerini bildiren teklifimiz için lütfen bizimle iletişime geçin. Markaya ait CYHCT-C2TC-U50A-5P kodu dışındaki diğer kod ve referanslar için de teklif almak isterseniz konusunda uzman satış personelimiz size teklif sunmaktan mutluluk duyacaktır. flir webcamWebPart number CYHCS-K200-10A CYHCS-K200-20A CYHCS-K200-30A CYHCS-K200-50A Nominal current 10A 20A 30A 50A Measuring range 0 ~ 20A 0 ~ 40A 0 ~ 60A 0 ~100A Nominal analogue output voltage +2.5VDC ± (1V ± 1.0%) Supply voltage +5V ±5% Galvanic isolation 50Hz,1min, 2.5kV ACCURACY DYNAMIC PERFORMANCE flir web client loginWebClosed Loop AC/DC Hall Current Sensor CYHCS-D8, Output: 100-200mA, Power Supply: ±15V ~ ±24V, Window: 40,5mm. This Hall Effect current … flir water leak detectionWebClosed Loop AC/DC Hall Current Sensor CYHCS-LTR100A, Output: 50mA-100mA, Power Supply: ±12V ~ ±18V, Window: 20.2mm This Hall Effect … flir warmtecameraWebClosed Loop AC/DC Hall Current Sensor CYHCS-D8, Output: 100-200mA, Power Supply: ±15V ~ ±24V, Window: 40,5mm This Hall Effect current sensor is based on closed loop compensating principle and can be used … great food tour of new york for one